Boiler water treatment that starts in the make-up.

Seven treatments covering feedwater, the boiler drum and the condensate return. Run one all-in-one product, or build the programme one condition at a time. Made in our own plants in Fujairah and Athens.

Talk to a specialist
Boiler Water Treatment Chemicals

Why it matters

Boiler water is the cheapest thing to get wrong.

Make-up water carries hardness, dissolved oxygen and whatever your softener let through. None of it announces itself. The first sign is a fuel bill climbing for no stated reason, or an unplanned shutdown.

Scale

A millimetre on a heat transfer surface costs fuel on every hour of production.

Oxygen

Dissolved oxygen pits the feed line and the drum from the inside.

Alkalinity

Too low and the water turns acidic, and hardness salts stay in solution instead of dropping out.

Carbonic acid

Condensate returns thin from the inside, and you lose the cheapest feedwater you have.

Sheran manufactures seven boiler water treatments at its own plants in Fujairah and Athens.

The range

Seven treatments. Two ways to run the programme.

Showing 7 of 7

Looking for a safety data sheet?

Material safety data sheets are issued on request, for any product in this range.

Where it acts

Every stage of the steam circuit.

From make-up to condensate return, each treatment works at a different point. Dose where the problem is.

Make-up, feed tank and hotwell. Hardness, dissolved oxygen, softener performance.

FEEDWATER

SC-BW-6041

SC-BW-6042

SC-BW-6043

SC-BW-6044

SC-BW-601

SC-BW-602

Mechanical oxygen removal. Scavengers deal with what is left.

DEAERATOR

SC-BW-602

Drum and heat transfer surfaces. Alkalinity, scale, sludge, silica.

BOILER

SC-BW-6041

SC-BW-6042

SC-BW-6043

SC-BW-6044

SC-BW-601

Amines carry over with the steam to protect what comes next.

STEAM

SC-BW-603

Return lines and feed system. Carbonic acid attack.

CONDENSATE

SC-BW-603

SC-BW-602

SC-BW-6041

Suitable for low, medium and high pressure steam boilers, hot water and process heating systems, and economisers.

Common questions

Dosage, testing and pressure.

If you want one dosing point, SC-BW-6041 or SC-BW-6042 covers oxygen, scale, sludge and alkalinity together. If you need to move one parameter without moving the others, such as raising alkalinity without adding phosphate, dose the single-purpose treatments separately.

Test, do not estimate. Hold boiler water pH at 10.5 to 11.5, phosphate residual at 20 to 50 ppm and condensate pH at 8.3 to 9.2. Every dose figure on this page is a starting point, to be corrected by the first test result.

SC-BW-602 is DEHA based. It adds almost no dissolved solids to the boiler, and because it is volatile it carries over with the steam and protects the condensate lines as well. Target dissolved oxygen below 0.007 ppm.

Yes. Send a sample with the working pressure and daily steam load and we will return the analysis with a dosing programme against it. We also supply test kits so your own team can hold the control limits between checks.

All seven come in 25 litre and 200 litre drums and 1,000 litre returnable IBCs. Other sizes are available on request.

Order

Tell us the boiler, we will tell you the programme.

Send the working pressure, the daily steam load and your last water analysis. We will come back with a dosing programme and a price, usually within one working day.