Hydrotesting chemicals and biocides for water that has to stay clean.

Four treatments: one for hydrotesting and wet lay-up, two biocides for cooling water and one algaecide for pools, fountains and ponds. Made in our own plants in Fujairah and Athens.

Talk to a specialist
Hydrotesting & Biocide

Why it matters

Standing water is where the damage starts.

Test water left in a pipeline or vessel corrodes steel and grows bacteria within days. In a cooling tower, slime and biofilm cut heat transfer and hide corrosion. Treat the water before it sits.

Corrosion

Hydrotest water left in a new pipeline pits the steel before the system has ever started.

Bacteria

Slime and bacteria grow fastest in warm, aerated, recirculating water.

Biofilm

A biofilm layer insulates heat exchangers and shelters corrosion underneath it.

Algae

Algae turns ponds, pools and fountains green and clogs the filters.

Sheran manufactures four hydrotesting and biocide treatments at its own plants in Fujairah and Athens.

The range

Four treatments. Test, protect, disinfect.

Showing 4 of 4

Looking for a safety data sheet?

Material safety data sheets are issued on request, for any product in this range.

Where it acts

From the test pump to the fountain.

Each treatment is matched to the water it goes into. Dose where the water sits or circulates.

New pipelines, tanks and vessels filled for pressure testing.

HYDROTEST

SC-2041

Systems left full of water before start-up or during shutdown.

LAY-UP

SC-2041

Warm, open, aerated water where slime grows fastest.

COOLING TOWER

SC-2042

SC-2043

Evaporative condensers and HVAC cooling circuits.

HVAC

SC-2042

Pools, fountains, ponds and artificial lakes.

PONDS & POOLS

SC-2044

Suitable for pipelines, storage tanks, pressure vessels, heat exchangers, cooling towers, HVAC systems, pools and ornamental water.

Common questions

Hydrotest, biocides and algae.

1,000 to 3,000 ppm for a standard hydrotest, 3,000 to 5,000 ppm for an extended test, and 5,000 to 10,000 ppm for wet lay-up and preservation. Adjust for water quality, test duration and metallurgy.

SC-2041 is formulated for wet lay-up as well as testing. At 5,000 to 10,000 ppm it protects carbon steel, stainless steel and copper alloys while the system waits for start-up.

Both are non-oxidising. SC-2042 is quaternary ammonium based and works across a wide pH range. SC-2043 is isothiazolinone based. Send us the system details and we will recommend one, or a programme that uses both.

Swimming pools, decorative fountains, ponds, artificial lakes and other recreational water. It is compatible with the pH adjusters and flocculants used in routine water treatment.

SC-2041 comes in 25 litre pails, 200 litre drums and 1,000 litre IBCs. SC-2042, SC-2043 and SC-2044 come in 30 kg and 200 kg drums and 1,000 kg IBCs.

Order

Tell us the system, we will tell you the treatment.

Send the water volume, the system type and what you are seeing. We will come back with a dosing programme and a price, usually within one working day.

Message on WhatsApp

Two production units

Fujairah and Athens

Certified

ISO 9001:2015

Trade Net ID

ShipServ TN-315946

Partner ID

ProcureShip PS ID 14754