Cooling water treatment for open towers and closed loops.
Six treatments for scale, corrosion and fouling in cooling towers, condenser circuits and closed hot and chilled water loops. Made in our own plants in Fujairah and Athens.
What are you treating?
Why it matters
A cooling circuit loses efficiency long before it fails.
Every cycle of concentration raises hardness and dissolved solids in the tower. Closed loops stay quiet until a pump seal or an exchanger tube lets go. Both are cheaper to treat than to repair.
Scale
Calcium carbonate on a condenser tube cuts heat transfer and raises the energy bill.
Corrosion
Mild steel pipework thins from the inside, and corrosion products foul what is downstream.
Yellow metals
Chlorine and bromine strip ordinary copper inhibitors, and brass tubes start to corrode.
Fouling
Suspended solids settle where flow is slow and hide corrosion under the deposit.
Sheran manufactures six cooling water treatments at its own plants in Fujairah and Athens.
The range
Six treatments. Open tower or closed loop.
Showing 6 of 6
1 / 6
Open recirculating systems and cooling towers
Open recirculating systems and cooling towers
SC-CW-708 Molybdate Scale & Corrosion Inhibitor
Full programme for open towers. Molybdate, phosphonate and a copper inhibitor in one liquid, for mixed metallurgy
Dose
100 to 500 ppm in circulating water
Pack
30 KG + 200 KG PE DRUM + 1000 KG IBC
Open recirculating systems and cooling towers
SC-CW-709 Open Loop Cooling Water Treatment
Scale, corrosion and suspended-solids control for open towers and condenser circuits in carbon and stainless steel
Dose
50 to 300 ppm in circulating water
Pack
30 KG + 200 KG PE DRUM + 1000 KG IBC
Open recirculating systems and cooling towers
SC-CW-704 Deposit Control & Antiscalant
Hardness scale and suspended solids building up on exchangers. Threshold inhibitor and dispersant, used with a corrosion inhibitor
Dose
5 to 25 ppm in circulating water
Pack
25 L + 200 L DRUM + 1000 L IBC
Open recirculating systems and cooling towers
SC-CW-703 HRA Copper Corrosion Inhibitor
Copper and brass tubes corroding in systems on chlorine or bromine. Halogen-resistant azole, added alongside the main programme
Dose
0.5 to 2.0 mg/L as active azole
Pack
25 L + 200 L DRUM + 1000 L IBC
Closed hot and chilled water loops
Closed hot and chilled water loops
SC-CW-701 Nitrite Closed-Loop Inhibitor
Nitrite-based, non-chromate. Passivates steel in closed hot water, chilled water and glycol systems
Dose
1.5 to 5.5 kg per m³, hold 600 to 1,800 ppm nitrite
Pack
30 KG + 200 KG PE DRUM + 1000 KG IBC
Closed hot and chilled water loops
SC-CW-702 Non-Nitrite Closed-Loop Inhibitor
Blend of organic and inorganic inhibitors for loops with mixed metallurgy, where nitrite is not wanted
Dose
1.0 to 3.0 kg per m³ of system water
Pack
30 KG + 200 KG PE DRUM + 1000 KG IBC
Looking for a safety data sheet?
Material safety data sheets are issued on request, for any product in this range.
Where it acts
Every part of the cooling circuit.
Open systems are dosed continuously at the basin or the recirculation line. Closed loops are dosed to a residual and topped up with the make-up.
Make-up water brings in hardness, alkalinity and suspended solids.
SC-CW-708
SC-CW-709
SC-CW-703
Main dosing point. Cycles of concentration build up here.
SC-CW-708
SC-CW-709
SC-CW-704
Treated water carries the inhibitor through every pipe.
SC-CW-708
SC-CW-709
SC-CW-704
SC-CW-703
The hottest surface, where scale and copper attack show first.
SC-CW-708
SC-CW-709
SC-CW-704
SC-CW-703
Hot and chilled water circuits, dosed once and topped up.
SC-CW-701
SC-CW-702
Suitable for cooling towers, evaporative condensers, condenser water circuits, HVAC loops and process cooling systems.
Common questions
Open, closed and copper.
Open towers lose water to evaporation and blowdown, so they need continuous dosing with SC-CW-708, SC-CW-709 or SC-CW-704. Closed loops hold their water, so SC-CW-701 or SC-CW-702 is dosed to a residual and topped up with the make-up.
SC-CW-701 is nitrite based and is controlled by testing the nitrite residual, 600 to 1,800 ppm. SC-CW-702 contains no nitrite and suits loops with mixed metallurgy. Both can be used in glycol systems.
Only if the system has copper or brass and runs on chlorine or bromine. Oxidising biocides break down ordinary copper inhibitors. SC-CW-703 is halogen resistant and is dosed alongside the main programme.
Yes. Send a make-up and a circulating water sample with the system volume and cycles of concentration. We return the analysis with a dosing programme against it.
SC-CW-701, 702, 708 and 709 come in 30 kg and 200 kg drums and 1,000 kg IBCs. SC-CW-703 and 704 come in 25 and 200 litre drums and 1,000 litre IBCs.
Order
Tell us the system, we will tell you the programme.
Send the system volume, the cycles of concentration and your last water analysis. We will come back with a dosing programme and a price, usually within one working day.